NFB-200H premium features and benefits
2" venting up to 65';
3” up to 150’ (including schedule 40 PVC).Vent Installation Detector (VID) for added safety.
Dual Venturi system creates better combustion control, turndown ratio and easy field gas conversions.
Patented stainless steel fire tube heat exchanger Navien’s innovative heat exchanger design is ASME‑Certified,“H” Stamped, and reduces high-stress point weld failures common on other combi-boilers.
Low gas pressure operation. Negative pressure regulating gas valve ensures maximum performance all the way down to 3.5" of water column on natural gas and 8" of water column on propane gas.
Low gas pressure operation. Negative pressure regulating gas valve ensures maximum performance all the way down to 3.5" of water column on natural gas and 8" of water column on propane gas.
Advanced user interface with Setup Wizard is made easy with backlit panel, click-wheel control and intuitive text.
Built-in control for a boiler pump, 3 zone pumps or 3 zone valves
NFB-200H QuickFacts
43.9cm W x 70.1cm H x 43.9cm D (17.3" W x 27.6" H x 17.3" D)
Product approvals
- CSA
- Yes
- SCAQMD 1146.2(NOx, <20ppm)
- Yes
- ASME Certified
- Yes "H" Stamp
- AHRI Number
- 206368829
- Canadian Registration Number
2087.94YT,
2087.91(BC)- Energy star certified
- Yes
Space Heating Ratings
- AFUE, %
- 95.0
- Heating Capacity
- 183,000 BTU/h
Model | NFB-200H |
---|---|
Heating | 13,300 - 199,900 BTU/h |
TDR | 15:1 |
Navien Condensing Boiler Space Heating Ratings | ||
---|---|---|
Model1 | NFB-200H | |
Heating Input | Min | 13,300 BTU/h |
Max | 199,900 BTU/h | |
Heating Capacity2 | 183,000 BTU/h | |
Net AHRI Rating, Water3 | 159,000 BTU/h | |
AFUE2, % | 95.0 | |
Other Specifications | ||
Water Pressure4 | Min | 0.4 kg/cm2 (6 PSI) |
Max | 5.6 kg/cm2 (80 PSI) | |
Water Connection Size (Supply, Return) | 1-1/4" NPT |
1 Ratings are the same for natural gas models converted to propane use.
2 Based on U.S. Department of Energy (DOE) test procedures.
3 The net AHRI water ratings shown are based on a piping and pickup allowance of 1.15.
Consult Navien before selecting a boiler for installations having unusual piping and pickup requirements, such as intermittent system operation, extensive piping systems, etc.
Item | NFB-200H | |
---|---|---|
Water volume | 17 l (4.5 gal) | |
Dimensions | 43.9cm W x 70.1cm H x 43.9cm D (17.3" W x 27.6" H x 17.3" D) | |
Boiler weight | 54.9 kg (121 lbs) | |
Installation location | Indoor wall-hung | |
Venting type | Forced draft direct vent | |
Ignition | Electronic ignition | |
Natural gas supply pressure (from source) | 3.5 " WC to 10.5 " WC | |
Propane gas supply pressure (from source) | 8 " WC to 13 " WC | |
Natural gas manifold pressure (min-max) | -0.03 " WC to -0.85 " WC | |
Propane gas manifold pressure (min-max) | -0.02 " WC to -0.75 " WC | |
Connection sizes | Gas inlet | 3/4" NPT |
Power supply | Main supply | 120V AC, 60Hz |
Maximum power consumption | Less than 15 amperes | |
Materials | Casing | Cold-rolled carbon steel |
Heat exchangers | Stainless steel | |
Venting | Exhaust | 2" or 3" PVC, CPVC, approved polypropylene 2" or 3" special gas vent type BH (Class III, A/B/C) 2" or 3" stainless steel |
Intake | 2" or 3" PVC, CPVC, polypropylene 2" or 3" special gas vent type BH (Class III, A/B/C) 2" or 3" stainless steel | |
Vent clearances | 0" to combustibles | |
Safety Devices | Flame rod, APS, ignition operation detector, water temperature high limit switch, exhaust temperature high limit sensor, water pressure sensor |
Navien reserves the right to change specifications at any time without prior notice.
Please refer to NavienInc.com to verify you have the most current information.
Navien reserves the right to change specifications at any time without prior notice.
NFB-200H FAQs
What is a boiler?
A boiler is a heating appliance that is used to heat water, which is then circulated throughout a piping system in a building. The heated water passes through some form of emitter, which will transfer the heat from the water into the building. The cooler water then returns to the boiler to be reheated. A boiler can be designed to heat the water using a variety of different energy sources, including natural gas, liquid propane, fuel oil, or electricity.
How does a boiler work?
A boiler is a relatively simple appliance, but will always include a few key components - a heat exhanger, burner, circulator (aka: pump), and some type of control system. When the building where the boiler is installed cools off, a control will tell the boiler to start. The pump (or pumps) will turn on to begin circulating water through the boiler and the building, and the burner will ignite to heat the water. The boiler control will operate to maintain the outgoing water at the temperature required for the application. As the heated water passes through the building, the rooms will warm up to a point where the control will turn the boiler off.
How long does a boiler last?
There are many factors that can affect the lifespan of a boiler, such as how well the unit is maintained, the water quality passing through the unit, and how well the system is designed to work with the boiler. Most Navien boilers have a 10-15 year residential warranty (depending on the unit). So a well maintained boiler in a properly designed and installed system could be expected to last up to 20 years or longer in some cases.
How do I turn on a boiler?
The operation of the boiler will be controlled by either a thermostat (or mulitple thermostats), or some type of boiler or building control system depending on the design. The Navien boilers have a power button on the front control panel to disable the operation of the boiler if necessary. Installing and service contractors also have access to a service switch inside the cabinet to shut off power to the boiler when needed.
How do I bleed a boiler?
Air in a boiler system can cause issues with overheating or preventing the pumps from being able to circulate water. All Navien boilers ship with an automatic air vent, which is typically mounted at the top of the boiler. The air vent can be used to purge air from the boiler (or bleed air) during the initial fill. Every boiler system requires an air eliminator to be installed in the piping system which will remove any remaining air as the water passes through.
How do I clean a water boiler?
To clean the outside of the boiler cabinet, a soft dry cloth can be used to wipe down the cabinet. Internal components should only be serviced by a qualified contractor.
How do I drain a boiler?
Water should only be drained from a boiler for service, or if the boiler will be turned off for an extended time frame and the system exposed to freezing temperatures. Generally, the boiler will have a drain valve or valves installed in the piping system below the boiler. Prior to draining, power must be turned off to the boiler and the drain valves can be opened. Opening a valve above the boiler may be required to allow the water to drain properly. Consult with a qualified contractor prior to, or if the boiler requires draining.
What is a condensing boiler?
A condensing boiler is designed to operate at a higher efficiency than a non-condensing boiler. This is achieved by using a heat exchanger that will transfer more heat from the exhaust into the water to be used to heat the structure. One of the by-products of a gas burner is water vapor, and when enough heat is removed from the exhaust that water vapor condenses inside the heat exchanger. The benefits of a condensing boiler are higher efficiency (operational cost savings), lower heat loss in the mechanical room, and lower exhaust temperatures.
What size boiler do I need?
Boilers are sized based on the amount of heat they can put out, measured in BTU's (British Thermal Units). The size of the boiler is determined by calculating the heat loss of the building, which is based on the size of the structure, the insulation value of the surfaces, and the door and window sizes. The size of the boiler required must exceed the heat loss to satisfy the system. A qualified contractor can perform a heat loss and help recommend a proper boiler size.
Where do I locate the Serial Number of my unit?
Please see the following attachment on where you can locate your serial number.
I am a homeowner and have a problem with my unit. If I call technical support, can they walk me through troubleshooting my unit?
Because our product involves water, electricity, and gas, there is only a limited amount of troubleshooting that can be done with a homeowner/end-user.
We recommend contacting your original installer or a Navien Service Specialist (NSS) to troubleshoot the unit.
NOTE: Charges will apply for service calls outside of 1 year labor period and/or non-warranty issues. Please see terms of our labor warranty.
Does Navien have Field Technicians available to service my unit?
Because our product involves water, electricity, and gas, there is only a limited amount of troubleshooting that can be done with a homeowner/end-user. We recommend contacting your original installer or a Navien Service Specialist (NSS) to troubleshoot the unit. NOTE: Charges will apply for service calls outside of 1 year labor period and/or non-warranty issues. Please see terms of our labor warranty.
I think there is a part that needs to replaced, how do I get a new part shipped out to me?
If you feel like there is an issue with your unit, please have someone contact Navien Technical Support while in front of the unit with your Serial Number ready. We recommend that a license contractor, original installer, or NSS contact is the person who calls us, so we may do in depth troubleshooting to determine if there is a part failure.
Navien Technical Support will be unable to send out parts without registration of product (Serial Number, Date of Installation, Homeowner Information, and Installer Information).